Search
Select Language

FLAGSHIP PRODUCT

TruScan Pro

Multi-Wavelength Pattern Scanning Photocoagulator with SP-Mode® Microsecond Laser Technology

Flagship Product

TruScan Pro

Multi-Wavelength Pattern Scanning Photocoagulator

TruScan Pro was built on PrismCore™ Multi-Wavelength Technology to consolidate up to four wavelengths with SP-Mode® Microsecond Laser Technology in one compact and versatile platform.

  • Better treatment for patients: SP-Mode® delivers a therapeutic effect that is safe and repeatable for glaucoma and retina procedures.
  • Up to four wavelengths in one console: 532nm, 577nm, 670nm, and 810nm, consolidate multiple devices into a single, versatile platform.
  • Integrated Delivery System (IDS): engineered with the world’s fastest pattern scanning technology to increase patient comfort and enhance a seamless workflow.
  • Dual-Port Console: designed for seamless compatibility with indirect ophthalmoscopes, glaucoma probes, and multiple endoprobes to maximize clinical performance.
  • Heads-Up Display (HUD): View live treatment images and real-time parameters directly through the binoculars, allowing you to maintain focus on the patient.
  • 15-inch Touchscreen LCD: intuitive control, customizable settings, integrated patient reporting, and expanded pattern selection to support precise, efficient treatment delivery.

SP-Mode® Microsecond Laser Technology

SP-Mode® delivers microsecond pulses that stimulate retinal pigment epithelium without visible burns, a gentler approach that preserves healthy tissue and reduces patient discomfort. Backed by peer-reviewed studies demonstrating efficacy across diabetic macular edema, central serous chorioretinopathy, and more.

Multi-Wavelength Platform

Four wavelengths, 532nm (green), 577nm (yellow), 670nm (red), and 810nm (infrared), each with distinct absorption characteristics for different conditions. One console replaces multiple standalone lasers, simplifying your practice while giving patients access to the right treatment for their specific condition.

See the touchscreen interface

Ultra-Fast Galvo Pattern Scanning

Galvanometer-based pattern scanning with parfocal continuously variable zoom spot control from 50 to 500 micrometers. Pre-programmed and customizable patterns mean shorter treatment sessions for patients and higher clinical throughput for your practice.

Integrated Delivery System (IDS)

Built-in optics and integrated laser safety filters provide a wide field of view and a five-step magnification changer for exceptional visualization. Designed within an ergonomic slit lamp, IDS offers clear, precise viewing of pathologies with fingertip illumination control, supporting confident, accurate treatment.

Heads-Up Display (HUD)

Optional accessory that displays treatment parameters directly through the slit lamp oculars. Physicians never need to look away from the patient during treatment, enhancing precision and contributing to safer, more comfortable procedures.

See the HUD

Dual Port System

Compatible with two delivery devices that switch instantly at the touch of a button, including slit lamp, laser indirect ophthalmoscope, endophotocoagulation probes, and cyclophotocoagulation probes. One versatile platform designed to support every delivery method with efficiency and precision.

3D Mouse for Comfortable Control

Designed for intuitive, precision-driven workflow, the 3D Mouse allows you to easily select and customize treatment patterns, including rotation, group selection, spacing, and radius adjustments. With simple touch control, you can seamlessly adjust power, duration, and interval settings for efficient, confident treatment delivery.

See the 3D mouse

Wheelchair-Accessible Smart Table

Single-column design accommodates patients of all mobility levels comfortably. The ergonomic layout reduces setup time between appointments, keeping your schedule moving efficiently.

Return on Investment

What Could TruScan Pro Mean for Your Bottom Line?

Calculate the revenue from procedures you’re currently referring out. Most practices see full ROI within 12–18 months.

Calculate Your ROI
12–18 months to full ROI for most practices

Technical Specifications

Max Power Output on Cornea 532nm: 2W  |  577nm: 2W  |  670nm: 0.7W  |  810nm: 3W
Wavelength 532nm (Green), 577nm (Yellow), 670nm (Red), 810nm (Infrared)
Mode of Operation Continuous Wave
Laser Type Solid-State Laser (532nm, 577nm, 670nm)  |  Diode Laser (810nm)
Pulse Duration 0.01 – 3.0s
Pulse Interval 0.01 – 3.0s & OFF (Single)
SP-Mode® Settings Port 1: Pulse Duration: 0.01 – 3.0s  |  Duty Cycle: 5%, 10%, 15%, 20%, 30%, 40%  |  Period: 0.01 – 3.0s & OFF
Port 2 (810nm only): Pulse Duration: 0.01 – 3.0, 3.5, 4.0, 4.5, 5.0, 10.0 – 90.0s  |  Duty Cycle: 5%, 10%, 15%, 20%, 25%, 30%, 31.3%, 40%  |  Period: 0.01 – 3.0, 3.5, 4.0, 4.5, 5.0, 10.0s & OFF
Pattern Scanning Single, Straight, Square, Triangle, Circle, Arc, Curve and Equal Square Spacing
Spot Size Single Spot: 50 – 500 µm
Limited Scanning Patterns: 100 µm (only Straight, Square, Triangle, Equal Square Spacing)
Scanning Patterns: 100, 200, 300, 400, 500 µm
Laser Safety Class Class 4
Aiming Laser Red laser diode (635nm), under 1.0mW continuously variable
Slit Lamp Illumination LED XLamp® XM-L2 2.85V 10W
Cooling System Fan cooled and TEC’s for Laser Diode and Crystal
Dimensions TruScan Pro Laser Console: 13 cm (H) × 40.5 cm (W) × 40 cm (D)
Complete System on Table: 140 cm (H) × 92 cm (W) × 63 cm (D)
Weight TruScan Pro Laser Console: 88 kg
Complete System on Table: 130 kg

Specifications subject to change. Refer to the operator manual for complete technical details.

Supporting Research for TruScan Pro

SP-Mode® Microsecond Laser Technology has been evaluated in peer-reviewed publications spanning diabetic macular edema, central serous chorioretinopathy, and other retinal conditions. Below are published studies relevant to the TruScan Pro platform.

Subthreshold Laser Therapy for CSCR

Clinical review evaluating subthreshold microsecond pulsing for chronic central serous chorioretinopathy, demonstrating subretinal fluid resolution while preserving retinal structure without visible laser burns.

Madani R, Ayoub A, Alasil T, Retina Today, 2024

Read Paper →

Comparison of One-Year Real-World Outcomes Between Red (670 nm) Subthreshold Micropulse Laser Treatment and Intravitreal Aflibercept Injection for Treatment-Naïve Diabetic Macular Edema

Retrospective study of 42 eyes comparing red (670nm) subthreshold micropulse laser to intravitreal aflibercept for treatment-naïve DME. Red SMPL maintained visual acuity and significantly reduced retinal thickness at 12 months, with outcomes equivalent to aflibercept injection.

Kikushima W, Furuhata Y, Shijo T, et al., Photodiagnosis and Photodynamic Therapy, 2025

Read Paper →

Choosing the Right Wavelength: Effectiveness of Yellow

Comprehensive review of yellow 577nm SP-Mode® subthreshold micropulse laser therapy, examining wavelength-specific advantages for retinal photocoagulation including selective absorption by melanin and oxyhemoglobin with reduced xanthophyll uptake.

Alasil T, Retina Today, 2020

Read Paper →

Comparison of the 1-Year Visual and Anatomical Outcomes Between Subthreshold Red (670 nm) and Yellow (577 nm) Micro-Pulse Laser Treatment for Diabetic Macular Edema

Retrospective chart review of 43 eyes comparing red (670nm) and yellow (577nm) subthreshold micropulse laser for DME. Both wavelengths maintained visual acuity and significantly reduced central retinal thickness at 12 months, suggesting comparable long-term efficacy.

Kikushima W, Shijo T, Furuhata Y, et al., Pharmaceuticals, 2021

Read Paper →

Hybrid Threshold Laser to Treat Diabetic Macular Edema: A Retrospective Analysis Single Center Cohort Study

Retrospective study of 12 eyes treated with hybrid threshold laser (532nm at 5% duty cycle) for DME. Retinal thickness reduced by approximately 20% at 24 weeks with minimal scar formation and stabilized macular edema.

Marashi A, Zazo A, Annals of Medicine and Surgery, 2022

Read Paper →

Short-Term Outcome (1 Year) of Yellow Subthreshold Pulsed Laser Treatment on Diabetic Macular Edema

One-year outcomes of yellow 577nm subthreshold pulsed laser treatment for diabetic macular edema using the TruScan 577 with SP-Mode® Microsecond Laser Technology.

Kikushima W, Tateno Y, Furuhata Y, Shijo T, 36th Annual Meeting, Japanese Society for Ocular Circulation, 2019

Read Paper →

Comparison of Intravitreal Bevacizumab Alone Versus Combined Bevacizumab and Macular Photocoagulation in Diabetic Macular Edema

Comparative study evaluating intravitreal bevacizumab alone versus combined bevacizumab and macular photocoagulation with TruScan for treating diabetic macular edema.

Akpolat C, Evliyaoglu F, Kurt MM, et al., Clinical J Ophthalmol, 2018

Read Paper →

View all clinical evidence

TESTIMONIALS

What Physicians Are Saying

“The TruScan laser provides the best optics I have used for a focal laser. The various patterns available speed up PRPs immensely and are very comfortable for patients. Visualization of the periphery is also excellent. The touch screen display is also extremely user-friendly and intuitive. Overall, it is a great machine.”

Dr. Harpal S. Sandhu

Harpal S. Sandhu, MD, FRCSC

University of Louisville, Kentucky

“The LIGHTMED TruScan Pro platform offers convenience, ease of use, and accuracy. The laser is well designed with attention to the ergonomic details. All treatments can be performed in any slit lamp position with a clean aiming beam and clear visualization. I have used several pattern scanning lasers in the past 20 years and this LIGHTMED laser is my favorite.”

Dr. Miguel Rechichi

Miguel Rechichi, MD, PhD

Centro Polispecialistico Mediterraneo, Italy

“I have been really happy with the LIGHTMED TruScan Laser, and I have been utilizing the Yellow 577nm wavelength to treat my patients with macular edema. The yellow wavelength has proven to be both safe and effective with excellent patient outcomes. The TruScan Laser has the widest range of wavelength choices to combat different retinal diseases.”

Dr. Tarek Alasil

Tarek Alasil, MD

Long Beach, California

“We have a large practice in Atlanta that encompasses all ophthalmic sub-specialties. All of our doctors are very pleased with the laser. It is quite convenient to have one console that meets the needs of all of our anterior and posterior doctors. Not only is the laser great, but the service LIGHTMED provides is impressive.”

Dr. Lawrence Woodard

Lawrence Woodard, MD

Omni Eye Services, Atlanta, Georgia

“LIGHTMED is a great company and they offer great service. Also the products are relatively low cost. They have very responsive and reliable distributors. In this ophthalmology teaching hospital, we see on average 400 patients per week. The patients are very satisfied and refer us to their family and friends for the Selective Laser Trabeculoplasty (SLT) treatment with LIGHTLas SLT and Sub-Threshold Pulse Laser Trabeculoplasty (SPLT) treatment with TruScan 577 and SP-Mode® Microsecond Laser Technology.”

Dr. José Francisco Ortega Santana

José Francisco Ortega Santana, MD

Hospital Nuestra Señora de la Luz, Mexico City, Mexico

Ready to Consolidate Your Laser Suite?

See how TruScan Pro can replace multiple devices with one powerful platform.