DERMATOLOGY & AESTHETICS
DermaLight
KTP Aesthetic Laser. Precise Vascular & Pigmented Lesion Treatment with SP-Mode® Microsecond Laser Technology
DermaLight
KTP Aesthetic Laser
The DermaLight delivers clinical-grade KTP therapy at a 532nm wavelength for the treatment of vascular and pigmented lesions. For patients, it provides effective treatment with faster recovery. For physicians, an ergonomic handpiece ensures precise control across a wide range of dermatologic and aesthetic indications. For practices, its compact, portable design and competitive price point make it easy to add or expand aesthetic laser services, with no disposable costs.
- 532nm KTP wavelength: optimal absorption for hemoglobin-targeted vascular treatments.
- 1mm and 3mm handpieces: precise spot size for targeted lesion treatment.
- Compact and portable: lightweight design with integrated carrying case.
- Intuitive touch screen: built-in protocols and customizable parameters.
KTP 532nm Wavelength
The 532nm green wavelength is preferentially absorbed by hemoglobin, making it ideal for treating vascular lesions including telangiectasias, spider veins, rosacea, and cherry angiomas. This wavelength penetrates superficial to mid-dermal layers while minimizing absorption by melanin.
Precision Handpieces
Two handpiece options provide flexibility for different treatment areas. The 1mm spot size enables precise targeting of small vascular lesions and facial telangiectasias, while the 3mm handpiece covers larger treatment areas efficiently.
See the handpiece →Diffusion Bonding Crystal Technology
Advanced laser crystal coating technology enhances beam quality and extends laser lifetime. The diffusion bonding process creates a stable, high-efficiency laser source with consistent power output over thousands of treatment hours.
Designed for Clinical Mobility
This compact console fits inside the included carrying case for effortless transport. Move easily between treatment rooms or off-site locations without additional infrastructure, maximizing flexibility while minimizing operational complexity.
See the carrying case →Touch Screen Interface
Intuitive control panel with pre-programmed treatment protocols for common indications. Customizable parameters can be saved for future use, ensuring consistent treatment settings across patient sessions and reducing setup time.
See the touch screen →Wireless Foot Pedal
This wireless function provides unrestricted movement throughout the treatment room. Eliminate cable clutter and positioning constraints while maintaining precise laser activation at the touch of your foot.
See the wireless foot pedal →532NM KTP TECHNOLOGY
Precision Targeting for Vascular & Pigmented Lesions.
The 532nm KTP wavelength is uniquely absorbed by hemoglobin and melanin chromophores, making it ideal for treating telangiectasia, spider veins, rosacea, age spots, and lentigines. DermaLight delivers controlled energy with minimal damage to surrounding tissue.
Clinical Evidence →DermaLight Technical Specifications
General Specification
| Electrical Input | 100 to 230 VAC 50/60 Hz Single Phase (Standard Power) |
| Power | 400W |
| Fuse Rating | T3.15AH250V @ 100-230 VAC (Time Lag) |
| Temperature Range | Transport: -10 to 70°C, Operating: 15 to 30°C, Storage: -10 to 55°C |
| Relative Humidity Range | Operating: 30% - 85% Non-Condensing Storage and Transport: Up to 95% Non-Condensing |
| Atmospheric Pressure | Operating: 800-1060 mbar, Storage and Transport: 500-1060 mbar |
| Cooling System | Fan Cooled and TEC’s for Laser Diode and Crystal |
| Dimensions (Total) | 130 mm (H) × 370 mm (W) × 330 mm (D) |
| Weight | 13 Kg / 29 lbs (System), 20 Kg / 44 lbs (Packed) |
Treatment Laser
| Laser Type | Diode Pumped Frequency Doubled YAG (KTP) |
| Wavelength | 532nm |
| Mode of Operation | Continuous Wave |
| Power Output | 5W Maximum |
| Power Adjustment | Variable from 0.05 to 5.0W |
| Exposure Duration | 0.01s to Continuous; and 0.2 to 10.0s in 0.1s increments |
| Repeat Interval | Off to 3s – Selectable from 0.01 to 3.0s |
| Operator Safety Glasses | OD4 at 532nm |
| Laser Safety Class | Class 4 |
| Power Display Accuracy | Better than +/-20% of Actual |
| Beam Divergence | < 0.2 NA |
Aiming Beam
| Laser Type | Red Laser Diode |
| Wavelength | 635–650nm (Red) |
| Mode of Operation | Continuous Wave |
| Power Output | Maximum of 1.0mW |
| Power Adjustment | Continuously Variable |
| Laser Safety Class | Class 2 |
Handpieces
| Spot Size | 1mm & 3mm |
| Fiber Length | 2 Meters |
| Beam Divergence | 0.2 NA |
Specifications subject to change. Refer to the operator manual for complete technical details.
Indications for Use
Vascular
- Telangiectasias
- Spider Veins
- Hemangiomas
- Rosacea
- Venous Lakes
- Scar Revisions
- Port Wine Stains
- Poikiloderma
Pigmented
- Sun Damage
- Lentigines
- Dyschromia
- Benign Pigmented Lesions
- Raised Lesions
- Dermatosis Papulosa Nigra (DPNs)
Other Treatments
- Active Acne
- Plantar Warts
- Scar Revisions
Before & After Results
Clinical results demonstrating the effectiveness of DermaLight KTP laser treatment for vascular and pigmented lesions.
Results may vary. Images courtesy of treating physicians.
Supporting Research for DermaLight
The DermaLight KTP laser is supported by published clinical experience in aesthetic and dermatologic applications. Below are articles from the LIGHTMED clinical library.
Affordable DermaLight KTP Laser Delivers High Efficacy and Ease of Use
Clinical review highlighting the DermaLight KTP laser’s efficacy for vascular and pigmented lesion treatment, with emphasis on its portable design and cost-effectiveness for aesthetic practices.
Frentzen, The Aesthetic Guide, 2017
Read Article →DermaLight Diode Laser Provides Solutions for Pigmented and Vascular Lesions
Overview of the DermaLight platform’s versatility in treating both pigmented and vascular lesions, with clinical cases demonstrating outcomes across multiple indications.
Wilson, The Aesthetic Guide, 2015
Read Article →TESTIMONIALS