Riboflavin Collagex

About Riboflavin Collagex

ribo

Riboflavin is an essential component of each corneal cross‐linking procedure, and the LightMed Collagex™ is redefined as the Ultra Hi-Quality Riboflavin solution. LightMed Collagex is exclusively produced and packaged by a “Class II” GMP accredited Manufacturing Pharmacy under fully aseptic conditions. It is supplied in convenient Glass Applicator syringe and in sterile packaging; available for use in conjunction with LightMed LightLink CXL™ Corneal Cross Linking system, or as generic formula.

The LIGHTMED Collagex Riboflavin Family

Collagex – Isotonic

Riboflavin 5-Phosphate (0.1%) with 20% Dextran T500 in 3ml Syringe
Ultra Hi‐Quality riboflavin solution for Normal Corneas of 350μm and above. In 1ml glass syringe.

World’s most unique isotonic composition for standard cross linking approach.
Helps to maintain or even slightly swell (up to 5%) the cornea.

  • In 3ml glass syringe applicator
  • Individually Packed in Sterile pouches

Collagex – Hypotonic

Riboflavin 5-Phosphate (0.1%)  Plus without in 1ml Syringe
Ultra Hi‐Quality riboflavin solution for treatment of thin corneas of below 400μm In 1ml glass syringe.

Indicated for use with thin corneas below (<400 um). Creating a corneal swelling effect by osmotic action.

  • In 1ml glass syringe applicator
  • Individually Packed in Sterile pouches

Collagex – Trans-Epithelial (TE)

Trans‐Epithelial Riboflavin Solution in 1ml and 3ml Syringe
Ultra Hi‐Quality Trans Epithelial‐ Hypotonic Solution for Cross Linking procedures WITHOUT corneal epithelial removal.

The trans-epithelial riboflavin solution assists in cross linking procedure reducing the need to remove the corneal epithelium. Reduces trauma and risk of post-op implications.

  • In 1ml glass syringe applicator
  • Individually Packed in Sterile pouches

Collagex – Rapid

(0.1%) Riboflavin with HPMC
Ultra Hi‐Quality riboflavin solution indicated for accelerated CXL (3min – 15min( 400μm In 1ml glass syringe.

A formulation especially designed for accelerated Cross Linking permitting reduced time treatment in as little a 3 minutes.

  • In 3ml glass syringe applicator
  • Individually Packed in Sterile pouches.

Collagex – Plus

(0.25%) Riboflavin
Ultra Hi‐Quality riboflavin solution indicated for LasikPlus (immediate post LASIK treatment)

A formulation especially designed for LASIK PLUS(procedure designed as extension of Lasik procedure intended to prevent Cornel Ectasia and improving Corneal Stability).

  • In 1m2 glass syringe applicator.
  • Individually Packed in Sterile pouches.

 

United States

San Clemente, California

1130 Calle Cordillera
San Clemente, CA 92673
USA

phone 949-218-9555

fax 949 218 9556

Japan

Tokyo, Japan

3F Orchis-Takebi, 2-Chome 22-1
Hatagaya, Shibuya, Tokyo 151-0072
Japan

phone +81 3 5333 2411

fax +81 3 5333 2412